Establishing Feasibility Study including technical operating factor tor setting up Geo-composite component facility for manufacturing Geo-Composite compounds related to the construction industry.
We addressed mechanical stabilized earth (MSE) walls using geosynthetic reinforcement which and failures. Our database has now grown extensively. We have presented the findings at two geotechnical conferences.
There are several GRI Standards in various forms of preparation. These include the following:
■ A practice on field seaming inspection emphasizing the electrical leak location system (ELLS).
■ Three standards on GCL joining so as to prevent/monitor panel separation.
■ A guide as to recommended testing of drainage geocomposites.
■ A practice explaining the use of MARV for geotextiles
■ A transverse rib bending test for homogeneous geogrids